PARAMUser parameter · EIA/ISO (F)
F95

EIA/ISO bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F95 is set bit by bit
  1. bit 0

    Interrupt function using user macro instruction, valid/invalid

    Interrupt function using user macro instruction 0: Invalid 1: Valid

    Range 0, 1 · Takes effect: At power on

  2. bit 1

    Handling of macroprogram interruption and call

    Handling of macro program interruption and call 0: Handled as interruption 1: Handled as subprogram call

    Range 0, 1 · Takes effect: At power on

  3. bit 2

    Automatic return position to restart the program (Fixed to 1)

    Automatic return position to restart the program (Fixed to 1) 0: Manual return 1: Automatic return

    Range 0, 1 · Takes effect: At power on

  4. bit 3

    G00 (positioning) command feed rate for dry run

    G00 (positioning) command feed rate for dry run 0: Rapid feed rate 1: Feed rate for dry run

    Range 0, 1 · Takes effect: At power on

  5. bit 4

    Wear offset check scheme with the input error prevention function enabled

    0: Window scheme 1: Alarm scheme [Related parameters] F81 bit 7: Input error prevention function valid/invalid F125: Permissible data alteration amount 2 for input error prevention F126: Maximum wear offset setting with the input error prevention

    Range 0, 1 · Takes effect: Immediate

  6. bit 5

    Alarm display when the slave or adaptor unit is not connected

    Alarm display when the slave or adaptor unit is not connected 0: Displayed 1: Not displayed

    Range 0, 1 · Takes effect: Immediate

  7. bit 6

    Manual-pulse interrupt amount cancellation with the RESET key, valid/invalid

    Manual-pulse interrupt amount cancellation with the RESET key 0: Invalid 1: Valid

    Range 0, 1 · Takes effect: At power on

  8. bit 7

    Coordinate system corresponding to G54 set with the RESET key, valid/invalid

    With the RESET key 0: Coordinate system corresponding to G54 1: Coordinate system unchanged

    Range 0, 1 · Takes effect: At power on