EIA/ISO bit settings (8 bits)
- bit 0
Interrupt function using user macro instruction, valid/invalid
Interrupt function using user macro instruction 0: Invalid 1: Valid
- bit 1
Handling of macroprogram interruption and call
Handling of macro program interruption and call 0: Handled as interruption 1: Handled as subprogram call
- bit 2
Automatic return position to restart the program (Fixed to 1)
Automatic return position to restart the program (Fixed to 1) 0: Manual return 1: Automatic return
- bit 3
G00 (positioning) command feed rate for dry run
G00 (positioning) command feed rate for dry run 0: Rapid feed rate 1: Feed rate for dry run
- bit 4
Wear offset check scheme with the input error prevention function enabled
0: Window scheme 1: Alarm scheme [Related parameters] F81 bit 7: Input error prevention function valid/invalid F125: Permissible data alteration amount 2 for input error prevention F126: Maximum wear offset setting with the input error prevention
- bit 5
Alarm display when the slave or adaptor unit is not connected
Alarm display when the slave or adaptor unit is not connected 0: Displayed 1: Not displayed
- bit 6
Manual-pulse interrupt amount cancellation with the RESET key, valid/invalid
Manual-pulse interrupt amount cancellation with the RESET key 0: Invalid 1: Valid
- bit 7
Coordinate system corresponding to G54 set with the RESET key, valid/invalid
With the RESET key 0: Coordinate system corresponding to G54 1: Coordinate system unchanged