PARAMUser parameter · EIA/ISO (F)
F96
EIA/ISO bit settings (7 bits)
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F96 is set bit by bit
- bit 0
Selection of variable number for tool offset amount
- bit 1
Fairing function valid/invalid
- bit 2
Processing for arc command blocks in high-speed machining mode, nonuniform feed/uniform feed
- bit 3
—
- bit 4
Selection of a corner judgment criterion in high-speed machining mode
- bit 6
Rotational axis shape correction valid/invalid
- bit 7
—
Source