PARAMUser parameter · EIA/ISO (F)
F99

Offset amount for the subprogram WNo. to the main WNo. concerned in case of output with subprogram in the EIA conversion function

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Offset amount for the subprogram WNo. to the main WNo. concerned in case of output with subprogram in the EIA conversion function

In case of output with subprogram in the EIA conversion function: Example : WNo. 10 When F99 is “20”. EIA conversion (The WNo. of the converted program is assumed to be 1000.) Main WNo. 1000 Sub WNo. 1020 Offset amount: 20 For the subprogram of the EIA conversion function, refer to F88 bit 0.

Setting
Setting range1 to 99999998
Unit—
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 36, 215. Reference and explanation only — not a reproduction of the manual.