PARAMUser parameter · SOFT LIMIT (I)
I13

SOFT LIMIT bit settings (4 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — I13 is set bit by bit
  1. bit 0

    Execution of G28 (reference-point return)

    Execution of G28 (reference-point return) 0: Memory-type zero-point return 1: Watchdog-type zero-point return

    Range 0, 1 · Takes effect: At power on

  2. bit 1

    Manual zero-point return operation

    Manual zero-point return operation 0: Memory-type zero-point return (After power-on, however, watchdog-type zero-point return) 1: Watchdog-type zero-point return

    Range 0, 1 · Takes effect: At power on

  3. bit 2

    Axis display when a control axis is removed

    Display of a removed axis 0: Not displayed 1: Displayed

    Range 0, 1 · Takes effect: At power on

  4. bit 6

    Removal of control axes, valid/invalid

    Removal of control axes 0: Not removed 1: Removed

    Range 0, 1 · Takes effect: At power on

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 45, 280. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →