PARAMData I/O parameter · OTHER (IOP/DPR/IDD)
IOP4

OTHER bit settings (4 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — IOP4 is set bit by bit
  1. bit 0

    Mazak data library function

    Mazak data library function 0: Invalid 1: Valid

    Range 0, 1 · Takes effect: At power on

  2. bit 1

    Outputting of Version.txt at saving on the DATA I/O display

    0: To output 1: Not to output

    Range 0, 1 · Takes effect: Immediate

  3. bit 2

    Parameter load error prevention function

    0: Valid 1: Invalid When the function is enabled, a warning window is displayed if loading is started with a parameter selected on the DATA I/O display.

    Range 0, 1 · Takes effect: Immediate

  4. bit 3

    Overwriting registration judgment criteria when entering tool data text with machines allowing registration of multiple tools

    0: TOOL, PART, NOM, ID CODE (+ATTRIB) 1: TOOL, PART, NOM, ID CODE (+ATTRIB), GROUP No.

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 98, 629, 630. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →