PARAMData I/O parameter · OTHER (IOP/DPR/IDD)
IOP5

OTHER bit settings (4 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — IOP5 is set bit by bit
  1. bit 1

    Tool data count check during tool data loading

    Tool count in tool data is checked when loading tool data in binary format. 0: Invalid 1: Valid * When tool data does not match the tool count checked during loading, alarm 505 CANNOT LOAD (MISMATCH) occurs.

    Range 0, 1 · Takes effect: Immediate

  2. bit 2

    Selection of the sign for the start point Z of point machining (XC, XY mode) when loading a Z offset scheme program

    Selects how the sign for the start point Z of point machining (XC, XY mode) is treated when the program of the Z offset scheme (MATRIX series) is converted into the WPC workpiece scheme program. 0: Does not invert the sign from the set value. 1: Inverts the sign from the set value.

    Range 0, 1 · Takes effect: At I/O startup

  3. bit 6

    Overwriting associated with loading of the program of the same work number

    Overwriting associated with loading of the same work number as that of the program(s) registered in the NC unit by hard disk, USB, or SD card input/output. 0: Alarm without overwriting 1: Overwriting

    Range 0, 1 · Takes effect: Immediate

  4. bit 7

    Overwriting associated with loading of the tool model of the same name

    Overwriting associated with loading of the tool model of the same name 0: Next tool model loaded without overwriting 1: Overwriting

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 98, 630, 631. Reference and explanation only — not a reproduction of the manual.