PARAMData I/O parameter · OTHER (IOP/DPR/IDD)
IOP6

OTHER bit settings (5 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — IOP6 is set bit by bit
  1. bit 1

    Program name change upon program conversion

    Appending the text string specified in the setting text file to the end of the program name at program conversion using the B-axis tilt table compatible program conversion function or EIA conversion (INTEGREX IV  INTEGREX i) 0: Do not append 1: Append * If the resulting program name exceeds 32 characters, the program name before the conversion will be truncated at its end and then the specified text string is appended at the end to bring the length of the program name to 32 characters. * The setting text file for the B-axis tilt table compatible program conversion function is stored in the following location. C:\ymw\M8Y\data\MC_sdg\EiaCnvVA2B\eia_cnvva2b_program_name .txt * The setting text file for the EIA conversion function (INTEGREX IV  INTEGREX i) is stored in the following location. C:\ymw\M8Y\data\MC_sdg\EiaCnvF2I\eia_cnvf2i_program_name.txt * This parameter is enabled only for the B-axis tilt table specification machines and the INTEGREX i Series horizontal multi-tasking machines.

    Range 0, 1 · Takes effect: Immediate

  2. bit 2

    Adding comments to the converted blocks upon EIA conversion

    Adding the comment “(_CNV)” to the converted blocks upon EIA conversion (INTEGREX IV  INTEGREX i) 0: Do not add 1: Add * This parameter is enabled only for the INTEGREX i Series horizontal multi-tasking machines.

    Range 0, 1 · Takes effect: Immediate

  3. bit 3

    EIA-compatible conversion menu display

    Displaying the EIA-compatible conversion menu upon EIA conversion (INTEGREX IV  INTEGREX i) 0: Not displayed 1: Displayed * When this function is enabled, all the EIA programs are converted with the menu item turned ON. To avoid erroneous operations, change the parameter setting only at the time of conversion. * This parameter is enabled only for the INTEGREX i Series horizontal multi-tasking machines.

    Range 0, 1 · Takes effect: Immediate

  4. bit 4

    Commenting out blocks containing variable numbers and operators upon EIA conversion

    Commenting out the blocks that contain variable numbers and operators upon EIA conversion (INTEGREX IV  INTEGREX i) 0: Commenting out the blocks and adding M9999 at the following block 1: Not commenting out * This parameter is enabled only for the INTEGREX i Series horizontal multi-tasking machines.

    Range 0, 1 · Takes effect: Immediate

  5. bit 5

    Commenting out T-command blocks upon EIA conversion

    Handing of T-command blocks that contain a D code upon EIA conversion (INTEGREX IV  INTEGREX i) 0: Commenting out the T-command block and adding M9999 at the following block 1: Commenting out only the D code * This parameter is enabled only for the INTEGREX i Series horizontal multi-tasking machines.

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 99, 631, 632. Reference and explanation only — not a reproduction of the manual.