Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — IOP8 is set bit by bit
  1. bit 0

    (Magazine-side display unit IN/OUT) Tool count/time data clear setting

    0: Do not clear 1: Clear

    Range 0, 1 · Takes effect: Immediate

  2. bit 1

    (Magazine-side display unit IN/OUT) Tool life count/time data clear setting

    0: Do not clear 1: Clear

    Range 0, 1 · Takes effect: Immediate

  3. bit 3

    B-axis tilt table compatible program conversion menu

    Display of [TILT.TBL A->B CONVERT] menu item on the DATA I/O display 0: Hidden 1: Displayed * Enabled only with B-axis tilt table specification machines.

    Range 0, 1

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 99, 633, 634. Reference and explanation only — not a reproduction of the manual.