PARAMMachine parameter · CALL MACRO (J)
J108

Maximum number of retrials to update the model with the SAFETY SHIELD function

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Maximum number of retrials to update the model with the SAFETY SHIELD function

When updating the model with the SAFETY SHIELD function at power-on, if “model update completion check interval (300 ms) * the number of retrials” counting from the start of update is exceeded, it will be regarded as a failure in model update and alarm 1106 SAFETY SHIELD FAILURE (3, , ) will be output. 0 or less : 50 times 1 or above : The setting value (J108) is regarded as the number of

Setting
Setting range–99999999 to 99999999
UnitTimes
Program type—
Takes effectAt power on
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 59, 385. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →