PARAMMachine parameter · CALL MACRO (J)
J108
Maximum number of retrials to update the model with the SAFETY SHIELD function
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Maximum number of retrials to update the model with the SAFETY SHIELD function
When updating the model with the SAFETY SHIELD function at power-on, if “model update completion check interval (300 ms) * the number of retrials” counting from the start of update is exceeded, it will be regarded as a failure in model update and alarm 1106 SAFETY SHIELD FAILURE (3, , ) will be output. 0 or less : 50 times 1 or above : The setting value (J108) is regarded as the number of
Setting
Setting range–99999999 to 99999999
UnitTimes
Program type—
Takes effectAt power on
Source