PARAMMachine parameter · CALL MACRO (J)
J119

Barrier-setting/cancelling M-code to be used for barrier teaching

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Barrier-setting/cancelling M-code to be used for barrier teaching

Specify the ID number of the barrier-setting and barrier-cancelling M-codes to be used for barrier teaching function. J119: Barrier-setting M-code to be used for barrier teaching (If a value other than 1 - 999 is set, the value will be regarded as 846.) J120: Barrier-cancelling M-code to be used for barrier teaching (If a value other than 1 - 999 is set, the value will be regarded as 847.)

Setting
Setting range1 to 999
Unit—
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 387. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →