PARAMMachine parameter · CALL MACRO (J)
J124

M codes for SPRINT control [Option]

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

M codes for SPRINT control [Option]

Set the M codes for SPRINT control. When parameter J124 = 0 M558: Start signal ON M559: Start signal OFF M574: Enable signal ON M575: Enable signal OFF M576: Select signal ON M577: Select signal OFF When parameter J124 ≠ 0 M [parameter J124 setting value]: Start signal ON M [parameter J124 setting value + 1]: Start signal OFF M [parameter J124 setting value + 2]: Enable signal ON M [parameter J124 setting value + 3]: Enable signal OFF M [parameter J124 setting value + 4]: Select signal ON M [parameter J124 setting value + 5]: Select signal OFF Note : Set the first M code number from which six consecutive unused M codes are available.

Setting
Setting range99999999 to 99999999
Unit—
Program type—
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 59, 388. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →