M codes for SPRINT control [Option]
M codes for SPRINT control [Option]
Set the M codes for SPRINT control. When parameter J124 = 0 M558: Start signal ON M559: Start signal OFF M574: Enable signal ON M575: Enable signal OFF M576: Select signal ON M577: Select signal OFF When parameter J124 ≠ 0 M [parameter J124 setting value]: Start signal ON M [parameter J124 setting value + 1]: Start signal OFF M [parameter J124 setting value + 2]: Enable signal ON M [parameter J124 setting value + 3]: Enable signal OFF M [parameter J124 setting value + 4]: Select signal ON M [parameter J124 setting value + 5]: Select signal OFF Note : Set the first M code number from which six consecutive unused M codes are available.
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 59, 388. Reference and explanation only — not a reproduction of the manual.