PARAMMachine parameter · CALL MACRO (J)
J126
SPRINT control enable signal ON/OFF delay time [Option]
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
SPRINT control enable signal ON/OFF delay time [Option]
Set the delay time before actually turning the enable signal ON/OFF after the execution of the M code for turning the SPRINT control enable signal ON/OFF. J125: Enable signal ON delay time J126: Enable signal OFF delay time
Setting
Setting range99999999 to 99999999
Unitms
Program type—
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 388. Reference and explanation only — not a reproduction of the manual.