PARAMMachine parameter · CALL MACRO (J)
J131-J140

Setting the M-code for making the INTELLIGENT SAFETY SHIELD function valid/invalid during automatic operation

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Setting the M-code for making the INTELLIGENT SAFETY SHIELD function valid/invalid during automatic operation

Specify the ID number of the M-code for making the interference check function valid/invalid. J131: INTELLIGENT SAFETY SHIELD function invalid J132: Material model cutting invalid J133: Machine interference check invalid J134: Machine interference check valid J135: Material model interference check invalid J136: Material model interference check valid J137: Fixture model interference check invalid J138: Fixture model interference check valid J139: Tool model interference check invalid J140: Tool model interference check valid

Setting
Setting range—
Unit—
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 59, 389. Reference and explanation only — not a reproduction of the manual.