PARAMMachine parameter · CALL MACRO (J)
J141
Selecting whether to output the M-code for making the INTELLIGENT SAFETY SHIELD function valid/invalid during automatic operation
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Selecting whether to output the M-code for making the INTELLIGENT SAFETY SHIELD function valid/invalid during automatic operation
Select whether the M-code registered in parameter J131–J138 to make the INTELLIGENT SAFETY SHIELD function valid/invalid during automatic operation is to be output from the NC to the PLC ladder. 0: Invalid (No output to the PLC ladder) 1: Valid (Output to the PLC ladder) 76 543 210
Setting
Setting rangeBinary, eight digits
Unit—
Program type—
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 59, 390. Reference and explanation only — not a reproduction of the manual.