PARAMMachine parameter · CALL MACRO (J)
J142

CALL MACRO bit settings (4 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — J142 is set bit by bit
  1. bit 0

    Selecting whether to output the M-code for making the INTELLIGENT SAFETY SHIELD function valid/invalid during automatic operation

  2. bit 1

    Selecting whether to output the M-code for making the INTELLIGENT SAFETY SHIELD function valid/invalid during automatic operation

    Select whether the M-code registered in parameter J139 and J140 to make the INTELLIGENT SAFETY SHIELD function valid/invalid during automatic operation is to be output from the NC to the PLC ladder. 0: Invalid (No output to the PLC ladder) 1: Valid (Output to the PLC ladder) 7 654 321 0

    Range 0, 1 · Takes effect: Immediate

  3. bit 2

    Output selection of M codes for temporarily disabling/canceling disabled status of INTELLIGENT SAFETY SHIELD function in automatic operation

  4. bit 3

    Output selection of M codes for temporarily disabling/canceling disabled status of INTELLIGENT SAFETY SHIELD function in automatic operation

    Selects whether to output the M codes for temporarily disabling/canceling the disabled status of INTELLIGENT SAFETY SHIELD in the automatic operation, which are registered in parameters J550/J551, from the NC to the PLC ladder. 0: Disabled (Not output to PLC ladder) 1: Enabled (Output M code registered in relevant parameter to PLC ladder) 76 543 210

    Range 0, 1 · Takes effect: Immediate