PARAMMachine parameter · MEASURE (K)
K104

MEASURE bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — K104 is set bit by bit
  1. bit 0

    Output of a laser measurement B-axis 0-degree command after ATC, valid/invalid

    Takes effect: Immediate

  2. bit 1

    Direction of the laser axis of the laser measuring instrument (L16/K104 bit 2)

    Takes effect: Immediate

  3. bit 2

    Direction of the laser axis of the laser measuring instrument (Parallel to the Y-axis/X-axis)

    Takes effect: Immediate

  4. bit 3

    Voice Adviser (Vocal output function) valid/invalid

    Takes effect: Immediate

  5. bit 4

    Type of voice

    Takes effect: Immediate

  6. bit 5

    Vocal guidance for warm-up operation

    Takes effect: Immediate

  7. bit 6

    Rapid feed command when cutting feed override is set to 0%, operation is executed/alarm state

    Takes effect: Immediate

  8. bit 7

    Feed rate for an approach to the starting point in EIA modal restarting mode

    Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 66, 433. Reference and explanation only — not a reproduction of the manual.