PARAMMachine parameter · MEASURE (K)
K105

MEASURE bit settings (7 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — K105 is set bit by bit
  1. bit 1

    Fixed value (1)

  2. bit 2

    S-code macro call invalid/valid

    0: Invalid 1: Valid

    Range 0, 1 · Takes effect: At power on

  3. bit 3

    T-code macro call invalid/valid

    0: Invalid 1: Valid

    Range 0, 1 · Takes effect: At power on

  4. bit 4

    Second auxiliary function macro call invalid/valid

    0: Invalid 1: Valid

    Range 0, 1 · Takes effect: At power on

  5. bit 5

    —

    Fixed value (0)

  6. bit 6

    Handling of the shaping control axis

    Select the value to be set (shaping control axis) at parameter K3. On the MACHINE PARAMETER display (“FEED VEL.” (M), “TIME CONST.” (N), etc.) where the axis data is set, 0: The identification number of the shaping control axis is handled as a number that does not include the axes for which data is not set. 1: The identification number of the shaping control axis is handled as a number that includes the axes for which data is not set. Refer to the explanation for parameter K3 for the example of setting. X Y Z B C V M1 M2 ・ ・

    Takes effect: Immediate

  7. bit 7

    Fixed value (0)

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 66, 67, 433, 434, 435. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →