K108
Permissible error range for synchronous control
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Permissible error range for synchronous control
Specify the maximum permissible error range for the master and slave axes for synchronous control (Tandem driving system). If the specified range is overstepped, alarm 141 EXCESS SIMULTANEOUS ERROR will be displayed. Note : Error checking will not occur if 0 is set.
Setting
Setting range0 to 65535
Unit0.0001 mm
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 67, 437. Reference and explanation only — not a reproduction of the manual.