PARAMMachine parameter · MEASURE (K)
K18

Specification of measuring tolerance (upper limit) [valid only for L106 bit 6 = 1]

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Specification of measuring tolerance (lower limit)

 With workpiece measurement 1. Tool compensation will be applied in the cases below.  –   –  1 2 1 2  K18  Compensation data   K17 100 100  –   –   1 2  K17  Compensation data   1 2  K18 2. Tool compensation will not be applied in the cases below.  –   –  1 2  K17 > Compensation data >  1 2  K17 100 100 3. Alarm will be caused in cases below. Compensation data > 1 2  K18  –    K18 > Compensation data where  = Tolerance upper limit  = Tolerance lower limit (Specified in program)  With tool measurement 1. Tool compensation will be applied in the cases below.    K18  Compensation data   K17 100 100   K17  Compensation data    K18 100 100 2. Tool compensation will not be applied in the cases below.    K17  Compensation data >   K17 100 100 3. Alarm will be caused in cases below. Compensation data >  K18   K18  Compensation data 100 : Tolerance (tool length/X-axis direction or tool Note : Judgment against the tolerance takes place in tool measurement only when L106 bit 6 = 1.

Setting
Setting range0 to 100
Unit%
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 61, 403. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →