Specification of measuring tolerance (upper limit) [valid only for L106 bit 6 = 1]
Specification of measuring tolerance (lower limit)
With workpiece measurement 1. Tool compensation will be applied in the cases below. – – 1 2 1 2 K18 Compensation data K17 100 100 – – 1 2 K17 Compensation data 1 2 K18 2. Tool compensation will not be applied in the cases below. – – 1 2 K17 > Compensation data > 1 2 K17 100 100 3. Alarm will be caused in cases below. Compensation data > 1 2 K18 – K18 > Compensation data where = Tolerance upper limit = Tolerance lower limit (Specified in program) With tool measurement 1. Tool compensation will be applied in the cases below. K18 Compensation data K17 100 100 K17 Compensation data K18 100 100 2. Tool compensation will not be applied in the cases below. K17 Compensation data > K17 100 100 3. Alarm will be caused in cases below. Compensation data > K18 K18 Compensation data 100 : Tolerance (tool length/X-axis direction or tool Note : Judgment against the tolerance takes place in tool measurement only when L106 bit 6 = 1.
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 61, 403. Reference and explanation only — not a reproduction of the manual.