PARAMMachine parameter · MEASURE (K)
K219
Coordinate measurement - plane inclination C, Skipping stroke limit
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Coordinate measurement - plane inclination C, Skipping stroke limit
Sets the limit of travel at a skip feedrate while executing coordinate measurement (plane inclination C measurement). If the touch sensor does not come into contact with the workpiece even after traveling this distance at a skip feedrate, the alarm 990 MACRO MEASUREMENT ALARM 1 occurs.
Setting
Setting range±99999999
Unit0.0001 mm/0.00001 in
Program typeM
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 68, 445. Reference and explanation only — not a reproduction of the manual.