PARAMMachine parameter · MEASURE (K)
K223

Coordinate measurement - plane inclination C, Permissible difference for skip coordinates X

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Coordinate measurement - plane inclination C, Permissible difference for skip coordinates X

Sets the permissible difference between the skip coordinates X at the first and second points while executing coordinate measurement (plane inclination C measurement). If the difference between the skip coordinates X exceeds the value set for this parameter, measurement is performed again. The set value is taken as an absolute value.

Setting
Setting range±99999999
Unit0.0001 mm/0.00001 in
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 68, 446. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →