PARAMMachine parameter · MEASURE (K)
K248
Involute interpolation minimum feedrate
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Involute interpolation minimum feedrate
Sets the minimum feedrate permitted in involute interpolation to clamp the acceleration. When the lower limit for the clamping feedrate is set for this parameter, the feedrate in the tangential direction is adjusted so that it does not go below the lower limit. Note : 1. When a value outside the setting range is set, 0 is assumed. 2. This parameter is valid when K247 > 0.
Setting
Setting range0 to 99999999
Unitmm/min
Program typeE
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 69, 454. Reference and explanation only — not a reproduction of the manual.