PARAMMachine parameter · MEASURE (K)
K250

Wait time before turning ON of zero-speed signal upon ending hobbing II (position controlled hobbing)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Wait time before turning ON of zero-speed signal upon ending hobbing (position controlled hobbing)

Sets the time to wait before the zero-speed signal of the hobbing axis (V-axis) turns ON upon specifying G113 (hobbing end) or interruption of hobbing during hobbing operation.

Setting
Setting range0 to 65000
Unitms
Program typeE
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 69, 454. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →