PARAMMachine parameter · MEASURE (K)
K29

Simultaneous control: Delay counter for automatic correction of synchronizing errors

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Simultaneous control: Delay counter for automatic correction of synchronizing errors

Delays master/slave axis position matching during automatic error correction (parameter K103 bit 1 = 0). Note : The delay time will be 3 seconds if 0 is set.

Setting
Setting range0 to 99999
Unit1.7 ms
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 61, 405. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →