PARAMMachine parameter · MEASURE (K)
K37

External deceleration speed

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

External deceleration speed

The upper-limit value of the feed rates available while the external deceleration signal is ON Feedrate K37

Setting
Setting range0 to 120000
Unitmm/min
Program typeM, E
Takes effectAfter stop of movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 406. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →