PARAMMachine parameter · MEASURE (K)
K42

G31.1 skipping speed

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

G31.1 skipping speed

The feed rate during axis movement by G31.1 (multi-step skip function) If the same block as that of G31.1 contains an F command, then that feed rate becomes valid.

Setting
Setting range0 to 120000
Unitmm/min
Program typeE
Takes effectAfter stop of movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 62, 407. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →