PARAMMachine parameter · MEASURE (K)
K47
M-code for external workpiece measurement
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
M-code for external workpiece measurement
Specify the M-code that is output at the start and end of measurement in the external pattern of workpiece measurement unit. Measurement start: M-code of a “value set at parameter K47” is output. Measurement end: M-code of a “value set at parameter K47 + 1” is output. * If the set value is out of the range, this parameter is invalid. (Setting range: 100 to 998)
Setting
Setting range100 to 998
Unit—
Program typeM
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 62, 408. Reference and explanation only — not a reproduction of the manual.