PARAMMachine parameter · MEASURE (K)
K49
First number of the standby M-codes
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
First number of the standby M-codes
Set the first number of the M-codes to be used for the M-code standby function. Example : To use M950 to M995 as the standby M-codes set “950” in K49 and “46” in K50.
Setting
Setting range31 to 1000
Unit—
Program typeM, E
Takes effectAfter stop of movement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 62, 409. Reference and explanation only — not a reproduction of the manual.