PARAMMachine parameter · MEASURE (K)
K50

Total number of the standby M-codes

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Total number of the standby M-codes

Set the total number of M-codes to be used for the M-code standby function. Example : To use M950 to M995 as the standby M-codes set “950” in K49 and “46” in K50. Note : If “0” is set, the M-code standby function will be invalid.

Setting
Setting range0 to 1000
Unit—
Program typeM, E
Takes effectAfter stop of movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 62, 409. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →