MEASURE bit settings (8 bits)
- bit 0
G31.2 skip condition SKIP-2
In the execution of the G31.2 command, whether or not SKIP-2 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal
- bit 1
G31.2 skip condition SKIP-10
In the execution of the G31.2 command, whether or not SKIP-10 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal
- bit 2
G31.2 skip condition SKIP-3
In the execution of the G31.2 command, whether or not SKIP-3 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal
- bit 3
G31.2 skip condition SKIP-11
In the execution of the G31.2 command, whether or not SKIP-11 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal
- bit 4
G31.2 skip condition SKIP-5
In the execution of the G31.2 command, whether or not SKIP-5 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal
- bit 5
G31.2 skip condition SKIP-13
In the execution of the G31.2 command, whether or not SKIP-13 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal
- bit 6
G31.2 skip condition SKIP-6
In the execution of the G31.2 command, whether or not SKIP-6 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal
- bit 7
G31.2 skip condition SKIP-14
In the execution of the G31.2 command, whether or not SKIP-14 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 63, 417, 418, 419. Reference and explanation only — not a reproduction of the manual.