PARAMMachine parameter · MEASURE (K)
K71

MEASURE bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — K71 is set bit by bit
  1. bit 0

    G31.3 skip condition SKIP-2

    In the execution of the G31.3 command, whether or not SKIP-2 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal

    Range 0, 1 · Takes effect: After stop of movement

  2. bit 1

    G31.3 skip condition SKIP-10

    In the execution of the G31.3 command, whether or not SKIP-10 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal

    Range 0, 1 · Takes effect: After stop of movement

  3. bit 2

    G31.3 skip condition SKIP-3

    In the execution of the G31.3 command, whether or not SKIP-3 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal

    Range 0, 1 · Takes effect: After stop of movement

  4. bit 3

    G31.3 skip condition SKIP-11

    In the execution of the G31.3 command, whether or not SKIP-11 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal

    Range 0, 1 · Takes effect: After stop of movement

  5. bit 4

    G31.3 skip condition SKIP-5

    In the execution of the G31.3 command, whether or not SKIP-5 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal

    Range 0, 1 · Takes effect: After stop of movement

  6. bit 5

    G31.3 skip condition SKIP-13

    In the execution of the G31.3 command, whether or not SKIP-13 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal

    Range 0, 1 · Takes effect: After stop of movement

  7. bit 6

    G31.3 skip condition SKIP-6

    In the execution of the G31.3 command, whether or not SKIP-6 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal

    Range 0, 1 · Takes effect: After stop of movement

  8. bit 7

    G31.3 skip condition SKIP-14

    In the execution of the G31.3 command, whether or not SKIP-14 is used as the skip signal: 0: Not used as the skip signal 1: Used as the skip signal

    Range 0, 1 · Takes effect: After stop of movement

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 63, 64, 419, 420, 421. Reference and explanation only — not a reproduction of the manual.