PARAMMachine parameter · MEASURE (K)
K94

MEASURE bit settings (6 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — K94 is set bit by bit
  1. bit 0

    Selection of whether menu function is to be made invalid after operation has been stopped by [ATC STOP]

    If [ATC STOP] does not need to be deselected to restart the automatic operation that has been stopped by tapping [ATC STOP], set this parameter to “1” (only for applicable machines). 0: [ATC STOP] is to be made invalid 1: [ATC STOP] is not to be made invalid

    Range 0, 1 · Takes effect: Immediate

  2. bit 1

    Indexing in measurement unit

    Select indexing operation in measurement unit when the rotation position in index unit is blank. 0: Move to the zero point. 1: Do not move.

    Range 0, 1 · Takes effect: Immediate

  3. bit 2

    Program editing on the EIA MONITOR display during multi-system operation

    Selection for whether or not program editing is allowed on the EIA MONITOR display when any of the multiple control systems is executing automatic operation 0: Not allowed 1: Allowed

    Range 0, 1 · Takes effect: Immediate

  4. bit 3

    W-axis command code selection for the MDI mode

    Command code to be displayed in the MDI window when [W SUB] is selected in the MDI mode 0: G110B2 1: G110Z[B]2

    Range 0, 1 · Takes effect: Immediate

  5. bit 4

    Indexing in cases where the next machining is started without specifying an index unit after a measurement unit has been executed

    0: Reset to the B-axis angle that is valid before measurement. 1: Hold the B-axis angle at the time of measurement. * This parameter is valid only when the program is created in the WPC scheme.

    Range 0, 1 · Takes effect: Immediate

  6. bit 5

    Display/no display of a block start interlock alarm if tool life of a tool specified in the block has expired

    0: Displayed 1: Not displayed (A tool life alarm will be displayed.) * Only the alarm display is invalid while interlock remains valid. Alarm 135 BLOCK START INTERLOCK is not displayed on the ALARM or ALARM HISTORY display.

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 64, 65, 426, 427. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →