PARAMMachine parameter · MEASURE (K)
K95

MEASURE bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — K95 is set bit by bit
  1. bit 0

    Selection whether the difference in angle between the upper and lower turrets is to be incorporated into the current C-axis position display of HD2

    Takes effect: At power on

  2. bit 1

    Fixed value (0)

    Takes effect: At power on

  3. bit 2

    Tool position compensation during T-command execution, performed/not performed

    Takes effect: At power on

  4. bit 3

    Coordinate system update during handle pulse interrupt, performed/not performed

    Takes effect: At power on

  5. bit 4

    Fixed value (0)

    Takes effect: At power on

  6. bit 5

    Acceleration/deceleration time constant for handle pulse feed

    Takes effect: At power on

  7. bit 6

    Software limits for G30 execution valid/invalid

    Takes effect: At power on

  8. bit 7

    In-position check valid/invalid

    Takes effect: At power on

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 65, 428. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →