PARAMMachine parameter · TABLE (L)
L111

TABLE bit settings (3 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — L111 is set bit by bit
  1. bit 5

    T-code in the index unit to be executed before the pallet change unit

    0: Output 1: Do not output

    Range 0, 1 · Takes effect: Immediate

  2. bit 6

    Fixed value (1)

  3. bit 7

    Whether interference check is executed or not while tailstock pushing state is released

    While tailstock pushing state is released, interference check between the barrier and the software limit is 0: Executed 1: Not executed

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 75, 495. Reference and explanation only — not a reproduction of the manual.