PARAMMachine parameter · TABLE (L)
L117-L120
Software limit relative position check – Check target axis L117 1st set of axes L118 2nd set of axes L119 3rd set of axes L120 4th set of axes
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Software limit relative position check – Check target axis L117 1st set of axes L118 2nd set of axes L119 3rd set of axes L120 4th set of axes
Set the check target axis corresponding to the axis set as the check reference (parameter L113 to L116) for checking the software limit relative position. Specify the axis number by that of NC. The checking function will be invalid if the number is missing or if an invalid number is set.
Setting
Setting range0 to 16
Unit—
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 496. Reference and explanation only — not a reproduction of the manual.