PARAMMachine parameter · TABLE (L)
L13

Allowable angle for parallelism and right angle in manual measurement

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Allowable angle for parallelism and right angle in manual measurement

Set the allowable angle for calculation of parallelism and right angle to be measured manually. Note : When error angle is smaller than the setting angle, the parallelism and right angle are calculated.

Setting
Setting range0 to ±900000
Unit0.0001°
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 71, 465. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →