PARAMMachine parameter · TABLE (L)
L130

Acceleration/deceleration filter (1st stage), G0 time constant

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Acceleration/deceleration filter (1st stage) L129 G1 time constant L130 G0 time constant

This parameter functions as a filter to smoothen the waveform command specified for pre-interpolation acceleration/deceleration. <Type of feed and acceleration/deceleration> L = Post-interpolation Linear acceleration/deceleration S = Pre-interpolation S-shaped acceleration/deceleration Auto- G1 L S matic Manual Axis feed L Linear acc. & dec. S-shaped acc. & dec. Speed Speed

Setting
Setting range0 to 200
Unitms
Program typeM, E
Takes effectAfter stop of axis movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 76, 498. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →