PARAMMachine parameter · TABLE (L)
L140
Waiting time for the completion signal of M35 (tool breakage detection) from PLC
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Waiting time for the completion signal of M35 (tool breakage detection) from PLC
0: 50 ms 1: 50 ms 2: 100 ms 3: 150 ms
Setting
Setting range0 to 99999999
Unit50 ms
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 77, 501. Reference and explanation only — not a reproduction of the manual.