PARAMMachine parameter · TABLE (L)
L146

Smooth corner control function: Time constant for pre-interpolational linear control during cutting feed rate acceleration/deceleration

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Smooth corner control function: Time constant for pre-interpolational linear control during cutting feed rate acceleration/deceleration

Set the time constant for pre-interpolational linear control during cutting feed rate acceleration/deceleration when the Smooth corner control function is valid. [Related parameters] L75

Setting
Setting range1 to 5000
Unitms
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 77, 501. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →