PARAMMachine parameter · TABLE (L)
L17
Minimum angle of head indexing command (only for INTEGREX j)
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Minimum angle of head indexing command
Set a command unit of head indexing angle.
Setting
Setting range0 to 3600
Unit0.1°
Program typeM, E
Takes effectNext block
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 71, 466. Reference and explanation only — not a reproduction of the manual.