PARAMMachine parameter · TABLE (L)
L27

Timer setting for manual TOOL EYE measurement

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Timer setting for manual TOOL EYE measurement

During manual TOOL EYE measurement, even if the sensor turns on for a time shorter than that which has been specified in this parameter, that will not be regarded as sensor-on.

Setting
Setting range0 to 65535
Unit7.1 ms
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 71, 469. Reference and explanation only — not a reproduction of the manual.