PARAMMachine parameter · TABLE (L)
L31-L34
Use in machine manufacturer macro
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Use in machine manufacturer macro
The settings of these parameters can be read using system variables.
Setting
Setting range±99999999
Unit—
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 71, 470. Reference and explanation only — not a reproduction of the manual.