PARAMMachine parameter · TABLE (L)
L45

Index table angle command

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Index table angle command

Set the minimum unit of index table angle command for the indexing units, ANGLE in the end units and B-codes in the manual program unit. 0: 1° 1 to 8: 1/1000° (auxiliary equipment axis specifications) Note : Index table angle display on the POSITION display is valid only when L43 = 1 (index table angle display on). 0: 1° index table 1 to 7: Nth axis under auxiliary equipment axis specs. (N = 1 to 7) 8: Positioning table

Setting
Setting range0 to 8
Unit—
Program type—
Takes effect—
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 72, 472. Reference and explanation only — not a reproduction of the manual.