Input selection for HEAD OFFSET display
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Input selection for HEAD OFFSET display
This parameter limits input items on the HEAD OFFSET display. 0: Data just on item SPDL. CMD can be input. 1: All data can be input.
Setting
Setting range0, 1
Unit—
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 72, 476. Reference and explanation only — not a reproduction of the manual.