PARAMMachine parameter · TABLE (L)
L61
Output timing of AHC and APC
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Output timing of AHC and APC
Operation timing of automatic head change (AHC) and automatic pallet change (APC) 0: AHC first and then APC 1: APC first and then AHC 2: Simultaneous
Setting
Setting range0 to 2
Unit—
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 72, 476. Reference and explanation only — not a reproduction of the manual.