PARAMMachine parameter · TABLE (L)
L72

5-axis spline interpolation geometry compensation software acceleration/deceleration filter 2 time constant

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

5-axis spline interpolation geometry compensation software acceleration/ deceleration filter 2 time constant

Set the time constant to be used in the 5-axis spline interpolation mode. A setting value of 0 is invalid.

Setting
Setting range0 to 57
Unitms
Program typeE
Takes effectAfter stop of axis movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 73, 479. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →