PARAMMachine parameter · TABLE (L)
L73
Time constant for shape correction acceleration/deceleration filter 2
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Time constant for shape correction acceleration/deceleration filter 2
Set the time constant to be used when shape correction is on. A setting of 0 is invalid.
Setting
Setting range0 to 56
Unitms
Program typeM, E
Takes effectAfter stop of axis movement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 73, 479. Reference and explanation only — not a reproduction of the manual.