PARAMMachine parameter · TABLE (L)
L74
Cutting feed rate for pre-interpolational acceleration/deceleration control
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Cutting feed rate for pre-interpolational acceleration/deceleration control
Set the cutting feed rate for pre-interpolational acceleration/deceleration control.
Setting
Setting range1 to 999999
Unitmm/min
Program typeM, E
Takes effectAfter stop of axis movement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 73, 480. Reference and explanation only — not a reproduction of the manual.