L79

In-position width for changeover of the synchronized-tapping gain

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

In-position width for changeover of the synchronized-tapping gain

Set the In-position width for changeover of the synchronized-tapping gain. If 0 is set, 10 microns will be regarded as having been set.

Setting
Setting range0 to 255
Unit0.001 mm
Program typeM, E
Takes effectAt power on
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 73, 481. Reference and explanation only — not a reproduction of the manual.