PARAMMachine parameter · TABLE (L)
L80

Linear to arc deceleration rate

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Linear to arc deceleration rate

Set the deceleration rate at the linear to arc or arc to linear blocks of shape correction.

Setting
Setting range0 to 99999999
Unitmm/min / in/min
Program typeM, E
Takes effectAfter stop of axis movement
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 73, 481. Reference and explanation only — not a reproduction of the manual.